How to safely debug a square tube machine?
Published Time:
2020-09-03
Connect the power cord of the square tube machine to the power supply specified by the machine. Jog the motor to observe the direction of rotation. The direction of motor rotation should be consistent with the direction of the arrow on the motor label, or turn on the power switch after connecting the wires.
Connect the power cord of the square tube machine to the power supply specified by the machine, jog the motor to observe the direction of rotation. The motor rotation direction should be consistent with the direction of the arrow on the motor label, or turn on the power switch after connecting the wires.
Detailed Installation and Debugging of the Square Tube Machine:
1. Handling: It is recommended to use a forklift to handle the square tube machine.
2. Installation: The machine must be horizontally fixed to a stable foundation and grounded.
3. Oiling: Open the rear cover of the machine box and add 56 liters of No. 46 anti-wear hydraulic oil to the oil tank.

4. Electrical Connection: Connect the power cord of the square tube machine to the power supply specified by the machine, jog the motor to observe the direction of rotation. The motor rotation direction should be consistent with the direction of the arrow on the motor label, or turn on the power switch after connecting the wires. If the machine operates and the mold opening increases, the motor rotation direction is correct. If the machine does not operate, you only need to swap any two of the three hot wires.
5. Pressure Adjustment: The system pressure of the machine is 31.5 MPa, adjusted by the relief valve. Turn clockwise to increase the pressure, and counterclockwise to decrease the pressure. (The pressure has been adjusted at the factory. If you need to adjust the relief valve pressure, strictly prohibit exceeding 31.5 MPa when using this equipment.)